Aalborg OM-TCi is a vertical cylindrical steam boiler with a high capacity range. OM-TCi has been developed based on our well-proven technology and long experience.
Aalborg OM-TCi (formerly MISSION™ OM-TCi) is a vertical cylindrical steam boiler in the capacity range of 8,000 - 20,000 kg/h. It has been developed based on our well-proven technology and long experience.
The best features of the well-known UNEX™ CHB and MISSION™ OM boilers have been incorporated into the new boiler design.
How it works
Furnace
Aalborg OM-TCi consists of a large furnace with gas-tight membrane walls. A sufficient number of downcomers ensures safe natural circulation, and adequate furnace dimensioning guarantees good combustion, moderate loading and low material stresses.
Convection part
The cylindrical shell surrounds the smoke tubes. These smoke tubes have enhanced heat transfer features guaranteeing low exhaust gas temperature and thus high efficiency.
Burner
The standard boiler can be delivered with an Aalborg Industries burner with fully automatic operation and control. The burner is designed for a high turndown ratio with complete combustion at low oxygen levels. Alfa Laval Aalborg’s KB rotary cup burner or Aalborg KBSA steam atomizing burners are offered based on application or customer preference.
The Aalborg KBSA steam atomising burner is designed for use on our side-fired boilers and can be delivered premounted. The use of oil flowmeter and modulation of the atomizing steam pressure ensures a stable combustion at all loads, also in the lower end. All burner mountings are arranged to ensure easy
installation and maintenance.