Monitors essential electrical system parameters on a bright, waterproof, daylight readable OLED screen
Compact size enables mounting in any convenient location
Reverse polarity protected
Mounts in a common 1-1/8 in hole
Convenient amperage monitoring
Monitors -100A to 100A DC
Positive or negative side wiring
Specifications
Color - Blue
Meter - Current
Nominal Voltage - 12V DC
24V DC
Resolution - 0.1A
Intermittent Rating The maximum amount of current a switch is designed to carry for a minimum of a designated period of time. - 110A
Cranking Rating 30 sec Normally associated with 'cranking current' which is the current required by the starter circuit prior to engine starting. The cranking current varies significantly during the starting cycle. Initially, there is a large surge of current required to overcome the inertia and compression of the engine. This surge can be two to four times the average cranking current. Once the engine is turning there are peaks and valleys as the pistons go through the compression and exhaust cycles. The cranking current rating is used for sizing batteries, cables, and battery switches. - 175A
Accuracy - ± 2%
Input Voltage Range - 8-36V DC
Lifecycles - 10,000 hours
Operating Current - 15mA
Operating Temperature Range - -40°C – 70°C (-40°F – 158°F)
Weight - 0.70lb (0.32 kg)