500mm x 500mm RTM (Mechanically Clamped) outer shim-plate cavity thickness adjustment
A mechanically clamped panel mould with cavity adjustment using peripheral shim plates:
Both mould halves include oil/water heating channels or integral electrical heating with appropriate insulation.
The appropriate peripheral shim plate is used to define the panel cavity thickness. The mould seals to either side of the shim plate.
The mould is mechanically clamped and so can be used at positive pressures (maximum 3 bar)
Both mould halves are designed to maintain accuracy at positive pressures.
Injection is via a peripheral injection gate with a central vent.
The upper mould is hinged and supported on gas-struts for ease of operation.