The scope of application
Used to put out eatly fire
Approval Standard
1.1MO Chapter 4 of International Code For Fire Safety Systems and its Amendments.
2. IMO A.951(23) Improved Guidelines for Marine Portable Fire Extinguishers
3. GB 4351.1-2005 Portable Fire Extinguishcrs-Part 1: Performance and Construction
Extinguishant Wcight : 5kg
Working Press, of Body : 1.2Mpa
Water test Press, of Body: 2.1Mpa
Valid Injection Duration : > 13S
Valid Injection Distance : > 3.5m
Dclaycd-action time : < 5S
Rate of Residual Extinguishing Medium : < 15%
Material of Body : ST12
Fire Kxtinguishcr Rank : 3A 89B
Operating Température range : -20*C —*-55’C