CBZ series marine ex-proof axial fan (hereinafter referred to as “fan”), this is a new ex-proof fan adopts explosion precaution according to regulation on the basis of CZ type. It is manufactured according to GB3836.1-2010《Explosive environment, part 1: general requirements for equipment》, GB3836.1-2010 《explosive environment part 2: the flame-proof casing" d "protection equipment》 and Register of Shipping of China 《Steel vessel classification and construction rules》. The fan is approved by ex-proof inspection unit of the People's Republic of China, and gets certificate.
Components
Fan is mainly composed of casing, impeller, vane supporting feet and marine motor.
Function
It can be used to transport Group B T1~T4, Group C T1~T5 flammable, explosive gas in ships, vessels and platforms.
Advantages
Fan has the features of low noise, large air volume, big pressure head, high efficiency. It has good corrosion resistance, shock resistance, the running is stable and safe, reversible operation can be selected according to users’ requirements.
Fan can be made into various types for users to select: Ⅰtype(deck type)、II type(air duct type)、III type(separate cabins type)、IV type(olive type)、V type(upper outlet type)。
Basic parameters:
● air flow:500~180000m3/h
● total pressure:100~1050Pa
● power:0.55kW~90kW
● Power supply: standard configuration AC 3PH 380V/50Hz,AC 3PH 440V/60Hz,if need can choose:AC 3PH 415V/50Hz,AC 3PH 460V/60Hz,AC 3PH 480V/60Hz,AC 3PH 690V/60Hz.