The bunkering of environmental or cryogenic liquids and gases from ships requires a linked Emergency Shut Down (ESD) system to ensure a controlled shutdown of the transfer operation, in the case of a detected emergency. Designed according the IMO requirements (IGF) and complying to the ISO20519.
The iMSL® Small Scale solution is practical and has backward compatibility to the existing LNG and bunkering market. The iMSL® Small Scale has a 5 pin ‘SIGTTO type’ primary Electric link and a Pneumatic back-up link that are failsafe and independent as reasonable practical with independent connection points for Ship-to-Shore link.
The iMSL® Small Scale offers a common main panel suitable for LNG fueled vessels and LNG Bunkers including Ship-to-Ship installations, this is complimented by selectable options of ship-side or jetty-side connection points.
Mampaey Offshore Industries offers all types of industry standard connectors for ESD link including original Icore compatible 5 pin as defines in the SIGTTO guidelines.
Electrical Link
5 pin type link (Icore compatible)
Supplier or receiver (ship or shore type installations)
Pendant option
Connector box for each bunker station (e.g. Port & Starboard)
Pneumatic Link
Pneumatic control module with adjustable trip pressure settings with 1/2” MIL-C-51234 connectors.