Door blades manufactured from 2mm mild steel door skins filled with superwool insulation
Z section frame formed with 4mm mild steel
Door and frame fitted with 5 heavy duty lift-off hinges with grease nipple
Live leaf fitted with 3 point latching stainless steel system on inside face
External face fitted st/st lever handle
Door complete with LCN heavy duty door closer
Door frame fitted with weather seal and runner fitted front andback of door
1.0 bar pressure
Difference between A- and H-fire ratings
A-fire rated doors and walls are tested with a normal ISO standard fire temperature curve. H-fire rated items are tested with a Hydrocarbon fire curve. The exact difference is the temperature during the testing procedure, H-fire ratd doors and walls are tested at higher temperatures in a longer time period.
The fire doors and fire walls shall maintain its function with respect to fire resistance and structural integrity when exposed to a heat load characteristic for cellulosic (A-fire rating) or hydrocarbon (H-fire rating) fire.