GENERAL
Model type - 24 VDC Magnetic Latch Charging relay, link batteries
Circuit type - Bi stable ACR
INPUT
Battery input - 2
Switch Positions - 2
Manual overide - Locked off/on
I 10 Cranking rating 10 sec - 2500A
I 60 Cranking rating 1 min - 1100A
I 300 Cintermittent rating 5 min - 700A
I C continue rating - 500A
Vmno Voltage maxium Operation - 32VDC
Control Circuit Voltage - 20.2..32.9VDC
Operatiuon current continous - < 40mA
Operation current when charging - < 7 A
Remote Control switch when charging - 100 mA
Automatically combines battery banks when senses voltage levels are: - Above 27.0 for 30 sec. / Above 26.0 for 90 sec.
Automatically isolates battery banks when sensed voltage levels are: - Below 19.2V (undervoltage lockout) / Below 24.7V for 10 sec. / Above 32.4V (undervoltage lockout)
GENERAL
Ambient operation temperature - -20ºC … +40ºC
Storage temperature - -25ºC … +85ºC
Operating humidity - 95%, non condens
Live current switching - 100.000 cyles
MECHANICAL
Connections terminal stud - M10 (3/8’-.16)
Connections stud lenght - 23 mm
Maximum terminal Stud Torque - 15.5 NM (140 in-lb)
Terminal material - tin-plated copper
Enclosure width - 95.25 mm
Enclosure height - 138.94 mm
Enclosure depth - 51.56 mm
Weight - 0.8 kg
Drilling mounting centers - 114.3mm * 76.20mm
Mounting srews - 4 mm
Ingress Protection Class - IP66
Enclosure Colour - RAL9011 Graphite Black
Cable clearance - 28.4 mm (1.12’)
Ignition Protection - SA J1171
Markings - CE, Iso 8846