GENERAL
Transformer type - 2 winding toroidal isolation transformer
Construction method - Special vibration isolated mounting of transformer
Cooling method - Temperature controlled gradually regulated forced air cooling above 60° transformer core
WINDING DATA
Rated power - 3.6 kVA
Nominal current - 16 A / 32 A
Inrush current - Softstart included 95%
Ambient operating temperature - -10°C .. + 45°C, derating to 80°C
Storage temperature - -25°C to 85°C
Operating humidity - 95% max, non-condensing
Audible noise - <40.0 dB(A); 120°C
Overvoltage protection - Softstart is protected for overvoltage using fuse
Earthscreen between windings - Compliant to ABYC, can carry full fault current
Safety - Standards IEC 60079, IEC 60726
MECHANICAL
Protection degree - IP21
Connections input/output - 6 mm 2 max.
Cable gland entry - 22 mm
Dimensions (HxWxD) - 380 x 290 x 208 mm per unit
Mounting holes - M8
Weight - 28.6 Kg per unit
Enclosure construction - Aluminum sheet metal
Surface finishing - RAL9010 white + AE80104123621 black