CCS certificate approved
Second, the use of lamps and precautions:
1: The lamps use DC 12V voltage and can be used after being connected to the power supply equipment on the boat. The voltage fluctuation should not exceed plus or minus 10%. Excessive fluctuation will affect the performance and service life of the lamp.
2: Lights should be installed on the hull or at a prominent place to indicate orientation.
3: This product is a sealed product, do not disassemble and replace the bulb by yourself, otherwise it will affect the sealing performance of the lamp.
Project test conclusion
Power supply voltage DC 12V
High and low temperature cycle test Meets the requirements of MSC.81 (70) 0, 1, 1
Vibration test Meet the requirements of MSC.81 (70) 0, 4, 1
Oil resistance test Meets the requirements of MSC.81 (70) 0, 4, 6
Rain and water tightness test Conform to MSC.81 (70) 0, 4, 7 requirements
Fire test meets the requirements of MSC.81 (70) 0, 4, and 8
Luminous intensity test Meets the requirements of MSC.81 (70) 0, 4, 9
Chromaticity test Meets the requirements of MSC.81 (70) 0, 4, 10
Mold test Meet the requirements of MSC.81 (70) 0, 4, 2
Insulation resistance ≥200MΩ